Regardless of which Omni Links product you choose – our high-performance web hosting, managed servers, cloud servers, dedicated root servers, or colocation services – you can rely on our state-of-the-art and environmentally-friendly infrastructure. Our three data center parks in Nuremberg, Germany; Falkenstein/Vogtland, Germany; and Helsinki, Finland; as well as our location in Ashburn, VA, USA, provide you with multi-redundant network connections to important Internet exchanges. So your internet presence will benefit from speedy loadtimes and top performance.
Our Datacenter
Our Data Centers
- Data Center Park Nuremberg, Germany
- Data Center Park Falkenstein, Germany
- Data Center Park Helsinki, Finland
- Data Center Ashburn, Virginia, USA
PRIVATE PEERINGS (7640G), PEERING POINTS (3330G), TRANSIT (5600G)
POWER SUPPLY
- AC: 230V, 16A
- Redundant UPS facilities
- Battery mode: Approx. 15 minutes
- Standby power system
- Diesel power generator for autonomous mode
- Power is supplied via a raised floor system
CLIMATE CONTROL
- Energy efficient direct free cooling N+2 redundancy
- Cold aisle containment
- Under-floor air conditioning
- Higher than average raised floor system
- Monitoring of air temperature and server/distribution cabinets
COLOCATION RACKS
- 5,500 sq m of colocation floor space
- Optional location in Nuremberg, Falkenstein or Helsinki
- Up to 49 rack height units (1 U) in 19” racks
- Extra deep racks
- Optional cold aisle containment
- 24/7 access and on-site service
- Separate work and relax area
- Optional ISDN line installation
FIRE PROTECTION
- Modern early warning fire system; covers all data center park facilities and includes an automatic fire alarm system that uses aspirating smoke detectors
- Direct connection of the data center’s fire alarm system to the local fire and rescue coordination center; includes fault monitoring
- Fire detectors include alarms
- Separation of the various fire protection areas by fire proof doors
- Doors automatically shut when system detects smoke
- Handheld CO₂ fire extinguishers and portable wheeled CO₂ fire extinguishers in every data center unit
- DC units (buildings) separated from each other with a gap in between them to prevent fire from spreading (flashover) until fire department arrives
- Gaps between DC units adhere to required minimum distances
- Designated fire-fighting spaces for every data center; spaces kept clear at all times
- Rooms for transformers, medium-voltage stations, and battery rooms built with firewalls and fireproof doors
- Cable ducts in firewalls are sealed for at least 90 minutes
- Ventilation ducts in the firewalls equipped with self-closing fire dampers
- Designated Datacenter staff members are fire protection officers and helpers; they communicate regularly with local fire departments
- Fire protection plans for every data center; these take into account any differences in structural design
Due to local conditions, there may be differences between the various data center parks.
MANAGEMENT
- Bilingual personnel (German/English)
- 24/7 service by qualified personnel
- Installation work by qualified technicians
SECURITY
- Video-monitored high-security perimeter fencing around the entire data center park
- Entry via electronic access control terminals with a transponder key or admission card
- Ultra-modern surveillance cameras for 24/7 monitoring of access routes, entrances, security door interlocking systems and server rooms
DDOS PROTECTION
- Latest hardware appliances
- Sophisticated perimeter security technologies
- Automated system that can protect your web applications, websites, servers, and IT infrastructure
- Attempted botnet communications thwarted
CERTIFICATION
- Certified in accordance with DIN ISO/IEC 27001
- Internationally recognized standard for information security
- Certification for all of our data center parks and entire infrastructure
- Verification for our continuous assessment of and sustained improvements to security standards